Omnes componentes HV inclusi in soldato serbatorio ex aere 316L eliminant ingressum umoris, pulveris et pollutionis; fortitudo insulationis SF6 triplex est fortitudinis aeris, quae permittit compactam conceptionem, quae non afficitur ab altitudine, umiditate aut atmosphaeris corrosivis.
±0.1 mm tolerance via industrial robots ensures ≥99.5% dimensional accuracy and ≥99% part standardization; German electrostatic water-based paint achieves ≤5 μm uniformity and 0.3% defect rate for zero-maintenance appearance.
Adiuvat interruptores ABB, Siemens, Schneider et domesticos ZN85 sine modificatione serbatorii; interfacies praeverificatae integram validitatem testuum typicorum conservant et optimisationem pretii per totam vitam possibilitatem praebent.
Ductus liberationis pressionis independentes per compartimentum, interblocationes mechanicae/electricalis "five-prevention", et protectio IP4X/IP2X etiam cum porta aperta; confirmata per experimenta dielectrica sustentationis et experimenta vitae mechanicae ≥20 000 secundum IEC 62271.
SF6 arcus exstinguendi facultas 100× aeris permittit rapidam defectuum remotionem et frequens commutandi operationes; 50 kA interruptio capacitas confirmata est pro altis tensionibus industrialibus et renascibilis rete connexionibus.
Helium massae spectrometria confirmat <0.1%/annum SF6 perditae rationem in omni vase; testis gas tightness documentatus secundum IEC 62271-203 ad probandam 30-annorum operationem sine maintenance.
Rapportus de testu salis pulveris et cyclorum thermalium referentes ad exemplaria realia de partibus; spissitudo et adhaesio strati mensae secundum ISO 12944 ut idoneitas ad ambientes C5-M/CX confirmaretur.
Resistentia dielectrica, correns brevis temporis 50 kA, et durabilitas mechanica 20 000 cyclorum in laboratorio certificato a CNAS examinatae; raporti referuntur ad IEC 62271-1/203 et GB/T 3906.
Compatibilitas interfacis verificata pro singulis modulis interruptoris/disconectoris suffragatis; tempus interbloccationis et mensurationes spatii documentatae sunt ad operationem tutam certificandam, quocumque primario instrumento electo.
|
Nomen |
UNIT |
Unitas interruptoris oneris |
Unitas electrica combinata |
Unitas praeservatorii circuitus |
||
|
Voltage aestimatum |
kV |
|
12/24 |
|
||
|
Frequentia censita |
Hz |
|
50/60 |
|
||
|
Currens nominalis |
A |
630 |
≤125 |
630/1250 |
||
|
Nivel insulati nominati |
1-minute power frequency withstand voltage |
tensio retinenda frequentialis (inter phaseos et inter phaseos et terram) |
kV |
|
42/65 |
|
|
tensio retinenda frequentialis (inter interruptores) |
|
48/79 |
|
|||
|
tensionis Impulsus Fulguritis Resistentia (acme) |
tensio retinenda frequentialis (circuitus regulandi et auxiliarii) |
|
2/2 |
|
||
|
tensio retinenda impulsus fulminis (inter phaseos et inter phaseos et terram) |
|
75/125 |
|
|||
|
tensio retinenda impulsus fulminis (inter interruptores) |
|
85/145 |
|
|||
|
Classificatus brevis temporis perferentia cursus |
circulus principalis/4 s |
kA |
20/20 |
|
20/25 |
|
|
Circuítus terrae/4s |
20/20 |
|
|
|||
|
Circuítus connexiónis terrae/4s |
17.4/17.4 |
|
17.4/21.7 |
|||
|
Summa evaluationis tolerabilis in praesenti |
circuitus principalis |
KA |
50/50 |
|
50/63 |
|
|
circuítus terrae |
43.5/43.5 |
|
43.5/54.5 |
|||
|
Rated Short-Circuit Making Current |
kA |
50 |
80 |
50/63 |
||
|
Aestimatus brevis circui rupturae praesens |
A |
|
31.5 |
20/25 |
||
|
Ratum translatio current |
A |
|
1500/1400 |
|
||
|
Rated active load breaking current |
A |
630 |
|
|
||
|
Currentia interruptiva in circuitu clauso nominalis |
A |
630 |
|
|
||
|
Currentia interruptiva nominalis pro incensu cáblorum |
A |
10/25 |
|
|
||
|
Vita Mechanica |
interruptor oneris/interruptor terrae |
|
5000 |
5000 |
10000 |
|
|
interruptor isolans/interruptor terrae |
batch |
2000 |
2000 |
3000 |
||
|
Pressio nominalis gasis SF6 (valóre relativus ad 20°C) |
Pressio nominalis implendi |
MPa |
|
0.04 |
|
|
|
Pressio mínima ad functionem |
|
|
0.02 |
|
||
|
Gradus protectionis |
Cassa Obsignata |
|
|
IP67 |
|
|
|
Cápsula apparatus interruptivi |
|
|
IP4X |
|
||
|
Taux annuel relatif de fuite de gaz |
|
%/an |
|
≤0.01 |
|
|
|
Numerus |
Res |
|
UNIT |
Unitas interruptoris oneris |
Unitas electrica combinata |
Unitas praeservatorii circuitus |
|
1 |
Voltage aestimatum |
kV |
40.5 |
40.5 |
40.5 |
|
|
2 |
Frequentia censita |
Hz |
50 |
50 |
50 |
|
|
3 |
Currens nominalis |
A |
630 |
63 |
630 |
|
|
|
Nivel insulati nominati |
tension supportée en fréquence industrielle pendant 1 minute (entre phases, phase-terre) |
kV |
95 |
95 |
95 |
|
|
tension supportée en fréquence industrielle pendant 1 minute (à travers la coupure isolante) |
kV |
118 |
118 |
118 |
|
|
4 |
tension supportée en fréquence industrielle pendant 1 minute (circuits de commande et auxiliaires) |
kV |
2 |
2 |
2 |
|
|
|
Tension supportée en impulsion de foudre (phase-terre) |
kV |
185 |
185 |
185 |
|
|
|
Tension supportée en impulsion de foudre (à travers la coupure isolante) |
kV |
215 |
215 |
215 |
|
|
5 |
Aestimatus brevis circui rupturae praesens |
kA |
|
20 |
20 |
|
|
6 |
Courant thermique admissible nominal (interrupteur principal/interrupteur de terre) |
kA |
20/20 |
|
20/20 |
|
|
7 |
Duratio Interruptionis Nominalis |
S |
3 |
|
3 |
|
|
8 |
Courant de crête admissible nominal (interrupteur principal/interrupteur de terre) |
kA |
50/50 |
|
50/50 |
|
|
9 |
Courant de fermeture nominal en court-circuit (interrupteur principal/interrupteur de terre) |
kA |
50/50 |
|
50/50 |
|
|
10 |
Numerus nominatus clausurarum curtocircuitus (interruptor principalis/interruptor terrae) |
vice |
3/2 |
|
|
|
|
11 |
Ratum translatio current |
A |
|
750 |
|
|
|
12 |
Rated active load breaking current |
A |
630 |
|
|
|
|
13 |
Gradus experimenti arcus interni |
|
|
Gradus IAC AFL 20 kA/0,5 s |
|
|
|
|
Vita Mechanica |
Classis interruptoris circuitus (M2) |
|
|
|
10000 |
|
14 |
Classis interruptoris oneris (M2) |
vice |
5000 |
5000 |
|
|
|
|
Classis interruptoris terrae (M1) |
vice |
3000 |
3000 |
3000 |
|
|
15 |
PRESSIO INFLATIONIS |
Pressio nominata inflationis (pressio manometrica ad 20 °C) |
bar |
|
1.4 |
|
|
|
Pressio minima inflationis (pressio manometrica ad 20 °C) |
bar |
|
1.2 |
|
|
|
16 |
Taux annuel relatif de fuite de gaz |
|
%/anno |
|
0.01 |
|
|
17 |
Contentus umoris gasis SF6 (temperatura ambientis 20°C) |
|
pPM |
|
≤500 |
|
|
|
Gradus protectionis |
Cassettum gasi |
|
|
IP67 |
|
|
18 |
Cassettum hermeticum |
|
|
IP67 |
|
|
|
|
Cassettum apparatuum interruptorum |
|
|
IP3X |
|
|
ABB/Siemens/Schneider pro specificatis globalibus aut ZN85 pro efficacia costarum; omnia praescripta ad interfaciem cisternae et coordinationem interlock sine reingegneria.
Rating standardes 6–33kV, 630–4000A in barra bus, ruptura 31.5/50kA; configurationes speciales disponibiles secundum datos verificatos testis typici pro exigentiis retis singularibus.
Nano-ceramic + German paint for C5-M/CX zones; anti-condensation heaters and IP23D ventilation for humid/tropical sites; low-temperature lubricants for -40°C operation.
Embedded sensors for gas density, temperature, and partial discharge; Modbus/IEC 61850 communication; optional motorized operating mechanisms and remote position indication.
RAL color matching, bilingual labels, QR-coded digital manuals; custom compartment layouts for special relay, metering, or arc-flash protection requirements.
Dedicated handling tools included; spare parts kits tailored to primary apparatus brand; extended warranty packages backed by 80+ country service network.
Optional electrical interlocks for remote operation verification; arc-flash detection systems with <10 ms trip response; enhanced mechanical locks for high-security facilities.
Narra nobis requisita tui projecti—gradus tensionis, ambientis, codicis rete, aut temporis expeditionis—et nos solutionem praebemus quae conformis est et optima.