capsula ex ceramica nano-316L cum resistentia ad 50kA garantit fiduciam sine maintenance pro retibus compactis.

Conspectus
Clavis Applications
Why Choose?
INGENIARIA
Specificationes Technicae
Adaptatio ad mensuram
SUPPORT
Conspectus
TSTY SF6 Gas Insulated Switchgear uti-lizat sulfur hexafluoride ut sicut medium insulativum et arcus-extinguens, ad consequendum spatium occupatum 60% minorem quam aequivalentia aer-insulata, dum integra protectio IP4X manet. Omnes partes vivae hermetice clauduntur in tanca ex acciaio inoxidable 316L soldata, cum recubrimento nano-ceramico, validatum pro resistentia ad pulverem salinam per 3 000 horas et ad vitam operativam 30 annorum in ambientes littorales, industriales, aut alti-humiditatis.
Compatibile cum apparatus primariis ABB, Siemens, et Schneider, sustinet systemata 6 kV usque ad 33 kV cum currente busbar usque ad 4 000 A et capacitate interrumpendi cortocircuitus 50 kA. Interbloccationes mechanicae "quinque-preventionum" integratae, ductus independentes liberationis pressionis, et facultas operationis cum ostio clauso certificant securitatem personarum, dum constructio robotica ±0,1 mm garantit exactitudinem dimensionalem ≥99,5 % et installationem perfectam in loco per omnes projectus globales.
Clavis Applications
Haec instrumenta specialiter constructa sunt pro retebus 6–33 kV, quae spatium angustum aut ambientes asperos requirent, ubi hermetica clausura, extrema resistentia ad corrosionem, et compatibilitas cum pluribus marchis eos a typicis alternativis isolatis aere aut GIS pictis distinguit.
overview_pic_1
Transmission & Distribution Urban Substations
overview_pic_2
Renewable Energy Offshore Wind Platforms
overview_pic_3
Industrial Manufacturing Compact Power Centers
overview_pic_4
Statio electrica photovoltaica
overview_pic_5
Statio Subterranea
overview_pic_6
Distributio Potentiae Altae Densitatis in Centro Datorum
Cur Ratione TSTY SF6 GIS Eligeres?
Omnes unitates trolleos centraliter montatos, spatiosas comparte cabilorum, et integrationem monitoris intelligentis optativam praebent, ad decennia servitii fidabilis intra aedificia aut extra sub tegmine tutum.
Sigillatio Hermetica et Immunitas Ambientalis

Omnes componentes HV inclusi in soldato serbatorio ex aere 316L eliminant ingressum umoris, pulveris et pollutionis; fortitudo insulationis SF6 triplex est fortitudinis aeris, quae permittit compactam conceptionem, quae non afficitur ab altitudine, umiditate aut atmosphaeris corrosivis.

Fabricatio Praecisa per Robotica

±0.1 mm tolerance via industrial robots ensures ≥99.5% dimensional accuracy and ≥99% part standardization; German electrostatic water-based paint achieves ≤5 μm uniformity and 0.3% defect rate for zero-maintenance appearance.

Compatibilitas Universalis cum Apparatu Primario

Adiuvat interruptores ABB, Siemens, Schneider et domesticos ZN85 sine modificatione serbatorii; interfacies praeverificatae integram validitatem testuum typicorum conservant et optimisationem pretii per totam vitam possibilitatem praebent.

Securitas operativa verificata

Ductus liberationis pressionis independentes per compartimentum, interblocationes mechanicae/electricalis "five-prevention", et protectio IP4X/IP2X etiam cum porta aperta; confirmata per experimenta dielectrica sustentationis et experimenta vitae mechanicae ≥20 000 secundum IEC 62271.

Superior Arc Extinguishing Performance

SF6 arcus exstinguendi facultas 100× aeris permittit rapidam defectuum remotionem et frequens commutandi operationes; 50 kA interruptio capacitas confirmata est pro altis tensionibus industrialibus et renascibilis rete connexionibus.

commodum_pic
Engineering & Global Compliance
Omnis TSTY SF6 GIS fabricatio intelligens cum validatione plurium normarum integrat:
overview_pic_1
Sealing & Leak-Rate Verification

Helium massae spectrometria confirmat <0.1%/annum SF6 perditae rationem in omni vase; testis gas tightness documentatus secundum IEC 62271-203 ad probandam 30-annorum operationem sine maintenance.

overview_pic_2
Validatio strati et corrosionis

Rapportus de testu salis pulveris et cyclorum thermalium referentes ad exemplaria realia de partibus; spissitudo et adhaesio strati mensae secundum ISO 12944 ut idoneitas ad ambientes C5-M/CX confirmaretur.

overview_pic_3
Assurantia perfomantiae in examinibus typicis

Resistentia dielectrica, correns brevis temporis 50 kA, et durabilitas mechanica 20 000 cyclorum in laboratorio certificato a CNAS examinatae; raporti referuntur ad IEC 62271-1/203 et GB/T 3906.

overview_pic_4
Multi-Brand Apparatus Coordination

Compatibilitas interfacis verificata pro singulis modulis interruptoris/disconectoris suffragatis; tempus interbloccationis et mensurationes spatii documentatae sunt ad operationem tutam certificandam, quocumque primario instrumento electo.

Specificationes Technicae
Configurationes normales pro SF6 GIS: tensiones nominatae 6/10/15/20/33 kV, frequencia 50/60 Hz, usque ad 4000 A in busbar, capacitas interrumpendi 50 kA, gradus protectionis IP4X/IP2X, conformis normis IEC 62271-203, GB/T 3906, CE, SGS.
Sf6 gas insulated switchgear

Nomen

UNIT

Unitas interruptoris oneris

Unitas electrica combinata

Unitas praeservatorii circuitus

Voltage aestimatum

kV

 

12/24

 

Frequentia censita

Hz

 

50/60

 

Currens nominalis

A

630

≤125

630/1250

Nivel insulati nominati

1-minute power frequency withstand voltage

tensio retinenda frequentialis (inter phaseos et inter phaseos et terram)

kV

 

42/65

 

tensio retinenda frequentialis (inter interruptores)

 

48/79

 

tensionis Impulsus Fulguritis Resistentia (acme)

tensio retinenda frequentialis (circuitus regulandi et auxiliarii)

 

2/2

 

tensio retinenda impulsus fulminis (inter phaseos et inter phaseos et terram)

 

75/125

 

tensio retinenda impulsus fulminis (inter interruptores)

 

85/145

 

Classificatus brevis temporis perferentia cursus

circulus principalis/4 s

kA

20/20

 

20/25

Circuítus terrae/4s

20/20

 

 

Circuítus connexiónis terrae/4s

17.4/17.4

 

17.4/21.7

Summa evaluationis tolerabilis in praesenti

circuitus principalis

KA

50/50

 

50/63

circuítus terrae

43.5/43.5

 

43.5/54.5

Rated Short-Circuit Making Current

kA

50

80

50/63

Aestimatus brevis circui rupturae praesens

A

 

31.5

20/25

Ratum translatio current

A

 

1500/1400

 

Rated active load breaking current

A

630

 

 

Currentia interruptiva in circuitu clauso nominalis

A

630

 


---

Currentia interruptiva nominalis pro incensu cáblorum

A

10/25

 

 

Vita Mechanica

interruptor oneris/interruptor terrae

 

5000

5000

10000

interruptor isolans/interruptor terrae

batch

2000

2000

3000

Pressio nominalis gasis SF6 (valóre relativus ad 20°C)

Pressio nominalis implendi

MPa

 

0.04

 

Pressio mínima ad functionem

 

 

0.02

 

Gradus protectionis

Cassa Obsignata

 

 

IP67

 

Cápsula apparatus interruptivi

 

 

IP4X

 

Taux annuel relatif de fuite de gaz

 

%/an

 

≤0.01

 

 

Numerus

Res

 

UNIT

Unitas interruptoris oneris

Unitas electrica combinata

Unitas praeservatorii circuitus

1

Voltage aestimatum

kV

40.5

40.5

40.5

2

Frequentia censita

Hz

50

50

50

3

Currens nominalis

A

630

63

630

 

Nivel insulati nominati

tension supportée en fréquence industrielle pendant 1 minute (entre phases, phase-terre)

kV

95

95

95

 

tension supportée en fréquence industrielle pendant 1 minute (à travers la coupure isolante)

kV

118

118

118

4

tension supportée en fréquence industrielle pendant 1 minute (circuits de commande et auxiliaires)

kV

2

2

2

 

Tension supportée en impulsion de foudre (phase-terre)

kV

185

185

185

 

Tension supportée en impulsion de foudre (à travers la coupure isolante)

kV

215

215

215

5

Aestimatus brevis circui rupturae praesens

kA

 

20

20

6

Courant thermique admissible nominal (interrupteur principal/interrupteur de terre)

kA

20/20

 

20/20

7

Duratio Interruptionis Nominalis

S

3

 

3

8

Courant de crête admissible nominal (interrupteur principal/interrupteur de terre)

kA

50/50

 

50/50

9

Courant de fermeture nominal en court-circuit (interrupteur principal/interrupteur de terre)

kA

50/50

 

50/50

10

Numerus nominatus clausurarum curtocircuitus (interruptor principalis/interruptor terrae)

vice

3/2

 

 

11

Ratum translatio current

A

 

750

 

12

Rated active load breaking current

A

630

 

 

13

Gradus experimenti arcus interni

 

 

Gradus IAC AFL 20 kA/0,5 s

 

 

Vita Mechanica

Classis interruptoris circuitus (M2)

 

 

 

10000

14

Classis interruptoris oneris (M2)

vice

5000

5000

 

 

Classis interruptoris terrae (M1)

vice

3000

3000

3000

15

PRESSIO INFLATIONIS

Pressio nominata inflationis (pressio manometrica ad 20 °C)

bar

 

1.4

 

 

Pressio minima inflationis (pressio manometrica ad 20 °C)

bar

 

1.2

 

16

Taux annuel relatif de fuite de gaz

 

%/anno

 

0.01

 

17

Contentus umoris gasis SF6 (temperatura ambientis 20°C)

 

pPM

 

≤500

 

 

Gradus protectionis

Cassettum gasi

 

 

IP67

 

18

Cassettum hermeticum

 

 

IP67

 

 

Cassettum apparatuum interruptorum

 

 

IP3X

 

 

Customization & Optional Features
Omnis TSTY SF6 GIS ad ordinem fabricatur, optionibus quae facultates fabricae intelligentis reflectunt:
overview_pic_1
Primary Apparatus Selection

ABB/Siemens/Schneider pro specificatis globalibus aut ZN85 pro efficacia costarum; omnia praescripta ad interfaciem cisternae et coordinationem interlock sine reingegneria.

overview_pic_2
Voltage & Fault Rating Tailoring

Rating standardes 6–33kV, 630–4000A in barra bus, ruptura 31.5/50kA; configurationes speciales disponibiles secundum datos verificatos testis typici pro exigentiis retis singularibus.

overview_pic_3
Environmental Adaptation Packages

Nano-ceramic + German paint for C5-M/CX zones; anti-condensation heaters and IP23D ventilation for humid/tropical sites; low-temperature lubricants for -40°C operation.

overview_pic_4
Intelligentia Monitorandi Integratio

Embedded sensors for gas density, temperature, and partial discharge; Modbus/IEC 61850 communication; optional motorized operating mechanisms and remote position indication.

overview_pic_5
Aesthetic & Functional Customization

RAL color matching, bilingual labels, QR-coded digital manuals; custom compartment layouts for special relay, metering, or arc-flash protection requirements.

overview_pic_6
Maintenance & Service Optimization

Dedicated handling tools included; spare parts kits tailored to primary apparatus brand; extended warranty packages backed by 80+ country service network.

overview_pic_7
Safety & Interlock Enhancements

Optional electrical interlocks for remote operation verification; arc-flash detection systems with <10 ms trip response; enhanced mechanical locks for high-security facilities.

Support & Documentation
overview_pic_1
IEC-compliant datasheets and one-line diagrams
overview_pic_2
Full type-test reports (lightning impulse, etc.)
overview_pic_3
Installation, operation & maintenance manuals
overview_pic_4
Regional technical support: 24/7 engineering assistance + spare parts hubs in Asia, Africa, and the Middle East

Paratus est Specificare pro Tuo Projecto?

Narra nobis requisita tui projecti—gradus tensionis, ambientis, codicis rete, aut temporis expeditionis—et nos solutionem praebemus quae conformis est et optima.

Paratus est Specificare pro Tuo Projecto?