7-layer nano-composite coating (zinc-rich primer + epoxy intermediate + polyurethane topcoat + nano-sealer) passes ISO 9227 NSS 20,000-hour test; eliminates rust-through risk in C5-M marine/industrial environments, reducing lifecycle repaint costs by 80%.
Fully assembled, wired, and tested at factory per IEC 61330; reduces on-site installation time from weeks to <48 hours with only cable termination required—critical for remote mining sites or emergency grid restoration.
Customizable HV ring-main units (2–6 ways) and LV distribution boards (up to 24 outgoing feeders); supports radial, loop, or dual-feed schemes with optional auto-transfer switches for uninterrupted supply.
Footprint reduced by 40% vs. traditional brick-and-mortar substations; internal arc-proof design and IP54D protection enable safe installation in confined urban plots or adjacent to process equipment.
Beyond salt spray, enclosure validated for UV resistance (ISO 4892-2), thermal cycling (-40°C to +70°C), and dust ingress (IEC 60529 IP6X); proven operational in Ethiopian highlands, Gulf Coast refineries, and Australian outback mines.
Each batch of nano-coated panels undergoes adhesion (ISO 2409), thickness (ISO 2808), and cathodic disbondment (ISO 15711) testing; certificate of conformity issued per project with traceable batch numbers.
Base design complies with IEC 61330; Ethiopia EEU, Saudi SEC, or South African SANS variants use region-specific busbar sizing, clearance distances, and labeling without compromising core structural integrity.
Internal arc classification IAC AFLR verified per IEC 62271-202; pressure relief vents and flame barriers protect personnel during rare internal faults—mandatory for public-access commercial installations.
QR-coded enclosure links to as-built single-line diagrams, torque records, coating test certs, and video-guided maintenance procedures; multilingual support for multinational EPC teams.
|
No. |
Items |
Unit |
Value |
|
|
|
|
Primary |
KV |
40.5 |
|
|
|
Secon dary |
12; 0.69 |
|
|
1 |
Rated voltage |
Subsidiary circuit |
V |
110; 220; 380 |
|
|
|
High voltage circuit |
|
400~1250 |
|
2 |
Rated current |
Low voltage circuit |
A |
630~3150 |
|
3 |
Rated frequency |
Hz |
50 |
|
|
4 |
Rated power |
kVA |
1250; 1600; 2000~20000 |
|
|
|
|
Power freque ncy |
|
95 |
|
|
|
High voltage side impact |
|
185 |
|
|
|
Power frequency |
|
42 |
|
5 |
Rated insulation level |
Low voltage side impact |
kV |
75 |
|
|
|
High voltage side |
|
20; 25; 31.5 |
|
6 |
Rated short time withstand current |
Low voltage side |
|
25; 31.5; 40 |
|
|
|
High voltage side |
|
50; 63; 80 |
|
7 |
Rated peak withstand current |
Low voltage side |
kA |
63; 80; 100 |
|
|
|
Power frequency |
|
65 |
|
8 |
Insulation level of transformer |
Impact |
|
185 |
|
9 |
Insulation level of subsidiary circuit |
kV |
2 |
|
Core component brand assurance, Delixi low-voltage components, Bosida vacuum circuit breaker professional certification.
Oil-immersed (ONAN) or cast-resin dry-type; vector group Dyn11/Yyn0 selectable; tap changers (off-load/on-load) per voltage regulation needs.
Galfan steel + 7-layer nano-coating (standard); stainless steel 316L upgrade for offshore/splash zone; insulated sandwich panels for tropical heat mitigation.
Natural ventilation (standard); forced-air cooling, dehumidifiers, or HVAC for >40°C ambient or sensitive electronics; anti-condensation heaters for humid climates.
Relay protection (overcurrent/earth fault), SCADA RTU, or IoT gateway integration; arc-flash detection and auto-reclosing for grid resilience.
Double-door access with mechanical/electrical interlocks; internal lighting, emergency stop, and fire suppression system (aerosol/gas) per local safety codes.
Multilingual nameplates and O&M manuals; factory-assisted preparation for EEU, SEC, INMETRO, or other mandatory certifications; spare parts kits aligned with local supply chain.
Tell us your project requirements—voltage level, environment, grid code, or delivery timeline—and we’ll provide a compliant, optimized solution.