Indirect plate-type liquid cooling with parallel flow channels ensures ≤2.5°C cell-to-cell ΔT under 1C continuous discharge; eliminates hot spots and thermal runaway propagation risk; extends cycle life to 8,000+ cycles at 80% EOL versus 5,000–6,000 for air-cooled equivalents.
1000kWh nominal capacity in standard 20ft ISO container footprint achieves 215kWh/m³ volumetric density; reduces land use by 35% and foundation cost per kWh versus air-cooled systems; enables modular scaling from 1MWh to 100MWh+ without custom civil works.
Liquid cooling unit consumes 40% less parasitic load than equivalent-capacity forced-air systems; intelligent thermal management algorithm dynamically adjusts pump speed and chiller output based on real-time cell temperature and ambient conditions; improves net round-trip efficiency by 1.5–2.5%.
Cell-level aerosol suppression + pack-level gas detection + compartment-level water mist + system-level deflagration venting four-tier protection; UL 9540A tested thermal runaway propagation resistance; fire-rated EI60 partitions between battery and PCS compartments prevent cross-zone escalation.
Four-quadrant PCS supports PQ/VF/grid-forming modes with <20ms fault current injection; synthetic inertia emulation programmable per TSO requirement; certified black-start capability; FFR/SI/STATCOM functions pre-configured for major global grid codes.
Tier-1 LFP prismatic cells with 280Ah+ capacity and 8,000-cycle warranty; laser-welded busbars with torque-indicating fasteners; module-level contactor and fuse protection; IP67 module sealing for coolant leak immunity; 100% incoming cell testing including EIS and self-discharge screening.
Coolant loop pressure-tested at 1.5× working pressure for 24 hours; flow uniformity verification ensures <5% deviation across all parallel branches; glycol-water mixture concentration monitored via inline refractometer; leak detection sensors at every quick-connect fitting.
100% units undergo 4-hour rated charge/discharge cycle verification; thermal imaging scan under full load confirms ΔT compliance; protection relay coordination test; communication protocol validation; fire suppression system functional check; partial SOC shipping preparation per UN38.3.
| Parameter | Standard Configuration | Enhanced Configuration | Extreme Climate Configuration |
|---|---|---|---|
| Nominal Capacity | 1000 kWh (0.5C/25°C) | 1000 kWh (0.5C/25°C) | 1000 kWh (0.5C/25°C) |
| Usable Energy | 900 kWh (90% DOD) | 920 kWh (92% DOD) | 880 kWh (88% DOD) |
| Rated Power | 500 kW (0.5C) | 500 kW / 1MW Selectable | 500 kW |
| DC Voltage Range | 600–1000 V | 600–1200 V | 600–1000 V |
| AC Output Voltage | 400V / 690V | 400V / 690V / 800V | 400V / 690V |
| Round-Trip Efficiency | >96.5% (System Level) | >97% (System Level) | >96% (System Level) |
| Cooling Method | Indirect Liquid Cooling | Indirect Liquid + Phase Change | Enhanced Liquid + Trace Heating |
| Cell-to-Cell ΔT | ≤2.5°C @ 1C Continuous | ≤2.0°C @ 1C Continuous | ≤3.0°C @ –30°C Start |
| Cycle Life | 8,000 Cycles @ 80% EOL | 10,000 Cycles @ 80% EOL | 7,000 Cycles @ 80% EOL |
| Enclosure Rating | IP55 | IP55D | IP65 + Positive Pressure |
| Operating Temp | –30°C to +50°C | –30°C to +55°C | –40°C to +55°C |
| Dimensions (L×W×H) | 6,058×2,438×2,591 mm | 6,058×2,438×2,591 mm | 6,058×2,438×2,896 mm |
| Weight (Approx.) | 18,500 kg | 19,200 kg | 20,500 kg |
LFP 280Ah/306Ah/314Ah cell options; sodium-ion battery variant for extreme low-cost applications; extended-capacity 1200kWh configuration using higher-energy-density cells; second-life battery integration for circular economy projects.
Factory-programmed FFR/SI curves per local TSO requirement; STATCOM mode for nighttime voltage support; SOC-reserved emergency backup logic; market bidding API integration for ancillary service revenue optimization; islanding detection and auto-reconnection per IEEE 1547-2018.
Desert package (enhanced chiller capacity + G4 sand filtration + UV-stabilized coating); Arctic package (trace heating + low-temp coolant + insulated enclosure + cold-start boost circuit); Tropical package (anti-condensation dehumidifier + fungicide-treated filters + enhanced corrosion protection).
Per-module aerosol suppression + compartment water mist + system deflagration venting triple-layer protection; optional clean agent (FK-5-1-12) for sensitive indoor installations; battery room early warning interface with gas/particle dual detection; third-party fire engineering review report.
IEC 62351 compliant encrypted communication; unidirectional OT/IT gateway; secure boot + firmware signing for BMS/PCS controllers; physical tamper-evident seals; NERC CIP/IEC 62443 compliance documentation package.
Standard ISO container dimensions for global intermodal shipping; integrated lifting points certified for 4-point sling; pre-commissioned to 95%+ reducing site work to cable connection and parameter configuration; partial SOC shipping per UN38.3/DG regulations.
Bilingual nameplates/O&M manuals; FAT report with thermal mapping and efficiency curve; BIM-ready 3D model; cybersecurity compliance declaration; AI predictive maintenance algorithm license; spare parts list with MTBF-based replacement schedule.
Tell us your project requirements—voltage level, environment, grid code, or delivery timeline—and we’ll provide a compliant, optimized solution.