100/200/215kWh Aer-Cooled C&I Energy Storage | TSTY

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Selecite vostro obiectivo de projecto
Epistula electronica
Nomen
Nomen societatis
Telephonum
Project Details
0/1000
Aere-refrigeratus systema immagazinandi energiam 215 kWh / 200 kWh / 100 kWh
Aere-refrigeratus systema immagazinandi energiam 215 kWh / 200 kWh / 100 kWh

Plattforma BESS modularis, refrigerata aere, ad implementationem rapidam pro applicationibus C&I distributis et ad marginem retis

Conspectus
Clavis Applications
Why Select?
INGENIARIA
Specificationes Technicae
Adaptatio ad mensuram
SUPPORT
Conspectus
The TSTY Air-cooled Energy Storage System series (100kWh / 200kWh / 215kWh) is a compact, modular battery energy storage platform engineered specifically for distributed commercial & industrial (C&I), grid-edge, and light-utility applications where installation speed, footprint flexibility, and O&M simplicity take precedence over ultra-high energy density.
Unlike liquid-cooled systems designed for utility-scale bulk storage, this air-cooled platform leverages an optimized forced-air convection architecture with intelligent variable-speed fan control, achieving cell-to-cell temperature differential ≤3.5°C under standard operating conditions while eliminating coolant leak risks, glycol maintenance, and chiller parasitic loads entirely.
Available in three standardized capacity tiers—100 kWh for telecom/rural backup, 200 kWh for C&I peak-shaving, and 215 kWh for high-density distributed nodes—all variants share a common mechanical and electrical interface, enabling seamless parallel stacking from single-unit deployments to multi-MWh aggregated systems without custom engineering. Each unit integrates LFP battery modules, bidirectional PCS, BMS, EMS, fire suppression, and LV switchgear into a factory-preassembled IP54 enclosure rated for –20°C to +50°C outdoor operation.
With plug-and-play commissioning in under 4 hours and zero specialized thermal management infrastructure required, it delivers the fastest time-to-energization in its class for distributed energy projects across all terrain types.
Principal Applications per Industry
overview_pic_1
Renewable Energy Systems
overview_pic_2
Power Transmission & Distribution
overview_pic_3
Vestibulum odio
overview_pic_4
Oleum & Gas
overview_pic_5
Mining & heavy industry
overview_pic_6
Infrastructura Transportationis
Why Select TSTY Air-cooled ESS Series?
Zero Liquid Risk & Maintenance Simplicity

Architectura pura refrigerationis aere eliminat omnino percolationes refrigerantis, degradationem glycolis, defectus pompae et servitium frigoriferorum; minuit visitationes ordinatas operationis et manutenctionis (O&M) de 60% versus systemata refrigerationis liquidae; optima pro locis distributis non custoditis, ubi accessus ad opifices technicos est limitatus.

Intelligent Variable-Speed Thermal Management

Algorithmus AI gubernans ventilatores adaptat dynamice fluxum aeris secundum gradientem temperaturae cellularis in tempore reali, condiciones ambientales et profila cyclorum; conservat ΔT ≤3,5°C ad descensum continuum 0,5C dum consumptio potentiae auxiliaris minuitur de 25% versus dispositions velocitatis fixae; extendit vitam calendarium ad 6.000+ cycli ad 80% EOL.

Modular Parallel Scalability

Interfācium mechanicum/ēlectricum commune in variantibus 100/200/215 kWh permittit coniunctionem parallelam ad modum plug-and-play usque ad 10 unitātēs per omnem omnibus AC sine reconfigurātiōne magistri-et-servī; sustinet expansionem capacitātis per fāsēs, quae cum incrementō oneris aut cyclīs ūniversālis congruit; nullum ingenium ad hoc speciale nec adaptātiō necessāria est.

Rapid Plug-and-Play Deployment

Prae-commissum in fabricā ad 98% completum; installātiō et activātiō singulāris unitātis in minus quam 4 horīs, inclūsīs fixātiōnibus fundāmentī, coniunctiōne cāblī AC, et verificātiōne parametrōrum; nulla infrastructūra thermica specialis, nūllus implētus refrigerāntis, nec tubulātūra complexa requiruntur; minuit cōnsūmptum labōris EPC per 45%.

Compact Footprint & Flexible Siting

variant 215 kWh attingit densitatem volumetricam 180 kWh/m³ in armario ad usum exterius; spatium occupat 40% minus quam continentes refrigerati per liquidum aequivalentis capacitatis; permittit installationem in tectis urbani, areis parking, et areis apparatus ubi spatium angustum est, sine modificatione civilis.

commodum_pic
Engineering & Global Compliance
Each TSTY Air-cooled ESS unit is produced under a distributed-BESS specialized quality framework:
overview_pic_1
Conformitas Normis
  • Norma Producti: IEC 62619, UL 9540, UL 9540A, NB/T 42091
  • Prestatio PCS: IEC 62477, IEEE 1547-2018, EN 50549
  • Securitas Accumulatorii: UN38.3, IEC 62619, GB 38031
  • Certificatio Securitatis: CE (EU), UL/cUL (America Septentrionalis), CCC (Sina), EAC (CIS)
  • Codex Rete: praeparamus pro IEEE 1547, ENTSO-E RfG, GB/T 36558 necessitatibus generationis distributae
overview_pic_2
Cell & Module Specification

Cellulae prismaticae LFP gradus primi (optiones 280Ah/306Ah) cum garantiā cyclorum 6 000; barrae connexae per laser cum fissuris indicantibus momenta torsionis; protectio contactoris et fusibilis in gradu moduli; sigillatio moduli IP54 pro immunitate ad pulverem; examinatio omnium cellularum ad introitum, inclūsā aequātiō capacitatis et examinātiō autodischarge.

overview_pic_3
Airflow Uniformity Validation

Design ductuum simulātus per CFD certificat deviationem fluxūs aeris <5% per omnes positiones modularum; verificātiō per imaginēs thermāles sub onere plēnō confirmat conformitātem ΔT ad extremās temperāturās ambientēs nominālēs; MTBF ventilātorum >80 000 horārum cum retroalimentātiōne tachometrī redundānte ad dētectiōnem defectūs.

overview_pic_4
Probatio Acceptationis Fabricae

omnēs unitātēs per 2 horās verificātur in cyclō charge/discharge nominalī; scān thermicum confirmat ΔT ≤3.5°C; testus coordinātiōnis relē protectiōnis; validātiō protocolī communicātiōnis; examen functionālis suppressionis incendii; praeparātiō ad expeditiōnem ad partem SOC secundum regulātiōnēs UN38.3/DG.

Specificationes Technicae
Aere-refrigeratus systema immagazinandi energiam 215 kWh / 200 kWh / 100 kWh
Parametrum variāns 100kWh variāns 200kWh variāns 215kWh
Capacitas Nominalis 100 kWh (0.5C/25°C) 200 kWh (0.5C/25°C) 215 kWh (0.5C/25°C)
Utilis Energy 90 kWh (90% DOD) 180 kWh (90% DOD) 193.5 kWh (90% DOD)
Potentia Nominalis 50 kW (0.5C) 100 kW (0.5C) 100 kW / 150 kW Selectable
Ambitus Voltage DC 400–700 V 500–900 V 600–1000 V
Voltage Output AC 380V / 400V 380V / 400V / 480V 380V / 400V / 480V
Efficientia conversionis >95,5 % (Nivelis Systematis) >96 % (Nivelis Systematis) >96,2 % (Nivelis Systematis)
Modus refrigerationis Aer Fortis Intelligentis Aer Fortis Intelligentis Aer Variabilis Augmentatus
ΔT Cellula ad Cellulam ≤3,5 °C @ 0,5C ≤3,5 °C @ 0,5C ≤3,0 °C @ 0,5C
Cycle Life 6 000 Cycli @ 80 % EOL 6 000 Cycli @ 80 % EOL 6 000 Cycli @ 80 % EOL
Censura Foderiorum IP54 IP54 IP54D
Temperatura operationis –20°C ad +50°C –20°C ad +50°C –20°C ad +50°C
Dimensiones (L×W×H) 1 300 × 800 × 1 800 mm 2 200 × 1 000 × 2 000 mm 2 400 × 1 100 × 2 100 mm
Pondus (circa) 950 Kg 1 750 kg 1 950 kg
Maximi Unitatum Parallelarum Numerus 10 pro AC Bus 10 pro AC Bus 10 pro AC Bus
Customization & Optional Features
overview_pic_1
Capacity & Power Tier Selection

Field-selectable capacity of 100/200/215 kWh via software license unlock; dual-power rating option (e.g., 100 kW/150 kW) for applications requiring asymmetric charge/discharge profiles; future-proof hardware enables capacity upgrade without physical replacement.

overview_pic_2
Grid Interaction Functions

Curvae volt-var/watt-freq programmatae in fabrica secundum requisita utilitatis localis; protectio anti-islanding conformis IEEE 1547-2018; modus formandi rete optabilis pro responsione primaria ad frequentiam microretis; integratio API ad responsum ad postulatum pro programmatibus aggregantium.

overview_pic_3
Options for Climate Adaptation

Pacchetum ad climata frigida (calefactor contra condensationem + praecalidator aeris intrantis + ventilatores lubrificati ad temperaturas infimas); pacchetum ad climata calida (ventilator exhaustus potentiatus + scutum solare + stratum stabilizatum contra radium ultraviolettem); pacchetum ad zonas littorales (instrumenta ex acciaio inox + reticulum filtrans resistens corrosioni).

overview_pic_4
Enhanced Safety Packages

Suppressionem duplicem per modulum aerosol + agentis purgantis compartimenti; tabula monitionis praematura externa optionalis cum detectione gemina gasis/particulis pro installationibus interioribus; detectionem interruptionemque defectus arcus (AFDD) in circuitu DC integratam; reportum tertiae partis de examinatione ingeniaria ignis pro permittendo.

overview_pic_5
Flexibility in Communication and Monitoring

Native Modbus RTU/TCP, CAN, et Ethernet-IP protocol support; optional 4G/5G wireless module for remote sites without wired connectivity; cloud-based monitoring dashboard with mobile app alert; local HMI touchscreen for on-site diagnostics without laptop.

overview_pic_6
Optimization of Installation and Transport

Integrated fork slots and lifting lugs for pallet jack and crane handling; pre-assembled AC/DC cable connectors reducing field wiring time by 70%; stackable design for multi-unit vertical deployment in space-constrained sites; partial SOC shipping per UN38.3 for simplified logistics.

overview_pic_7
Documentation and Digital Deliverables

Bilingual nameplates and quick-start guide; FAT report with thermal mapping and efficiency verification; BIM-compatible 3D model for layout coordination; cybersecurity compliance declaration per IEC 62443; spare parts list with preventive maintenance schedule.

Support & Documentation
overview_pic_1
IEC-compliant datasheets and one-line diagrams
overview_pic_2
Full type-test reports (lightning impulse, etc.)
overview_pic_3
Installation, operation & maintenance manuals
overview_pic_4
Regional technical support: 24/7 engineering assistance + spare parts hubs in Asia, Africa, and the Middle East

Paratus est Specificare pro Tuo Projecto?

Narra nobis requisita tui projecti—gradus tensionis, ambientis, codicis rete, aut temporis expeditionis—et nos solutionem praebemus quae conformis est et optima.

Paratus est Specificare pro Tuo Projecto?