Amorphus legatus siccus-transformator
Amorphus legatus siccus-transformator

Designum igni-resistens minuit perditas sine onere de 60–70% pro centris datorum et infrastructuris sustinibilibus.

Conspectus
Clavis Applications
Why Choose?
INGENIARIA
Specificationes Technicae
Adaptatio ad mensuram
SUPPORT
Conspectus
TSTY Amorphous Alloy Dry-Type Transformer substituit cores conventionales de acciaio silicio per cores de metallo amorfo a base di ferro ad alte prestations, attingens 60–70% minor perdites in status sine onere et corrente de excitatione notabiliter minuenda, dum integritas dielectrica plena manet sine insulatione liquida. Fabricatus specialiter pro ambientes ubi transformator est semper activus (24/7) sed sub oneribus variabilibus, offert meliorationes mensurabiles del indice PUE in centra de datos magni, centra de computatio, et aedificia viridia, ubi perdites in status sine onere dominent consummationem annualem energiae.
Constructio per coil fusus praebet fortitudinem mechanicam superiorem, resistentiam ad umorem, et capacitatem ad sustinendum impulsus de fulmen, permittens deploymentem internum securum in facillitates urbanas altissime densas. Omnes unitates sunt sine maintenance, auto-refrigeratae vel auxiliatae per ventiles, et conformes ad normam IEC 60076-11 pro applicationes igni-sicuras et sensibiles ad ambientem.
Clavis Applications
Communiter specificatus pro projectibus quae ultra-minimos perditos in statu quietis, securitatem contra incendia, et verificatas metrices sustentabilitatis praeposuerint ante alternativa tradita oleo plena aut ex accipitro ferro siccis.
overview_pic_1
Centra Magna Datōrum et Infrastructūra Computātōris
overview_pic_2
Commercial & high-rise buildings
overview_pic_3
Transmission & Distribution Systems
overview_pic_4
Renewable Energy Integration
overview_pic_5
Vestibulum odio
overview_pic_6
Rete Intellegens et Utilitates
Why Choose Amorphous Alloy Dry-Type Transformer?
All units feature copper or aluminum windings per specification, F/H-class insulation systems, and IP20/IP23D enclosures for decades of reliable, hands-off service.
reductio perditae in operatione sine onere: 60–70%

Nucleus metallicus amorpha ostendit paene-zero amissio hysteresis versus ferrum silicium orientatum granulatum, praebens annuas conservationes energiae quantificabiles, praesertim valde utiles in infrastructura digitali semper-activa cum onere medio levi.

Designum igni-resistens et eco-safum

Capsulatio bobinae resinosae fusae eliminat liquida inflammabilia et emissiones toxicae, adimplens codices igneos interiores severissimos et certificationes sustentabilitatis sine detrimento perfomantiae thermalis aut fortitudinis dielectricae.

Resilientia mechanica et environmentalis praestantior

Structura monolithica bobinae resistit viribus electromagneticis durante defectibus et impedit ingressum umoris in climatibus humidis, assurans fiduciam longae durationis ubi nuclei laminati conventionales degenerant.

Operatio per totam vitam sine maintenance

Constructio coil hermetice et refrigeratio passiva/auxiliata per ventilatorem nullum examen olei, nullam substitutionem iuncturarum, nullum servitium desiccantis requirunt, quod OPEX et tempus inoperationis in facillitatibus missionis-criticis minuit.

Alta insulatio et impulsus toleratio

Geometria avolutorum et compositio resinis optima gradus BIL melioratos efficiunt, quae electronica subtilia infra se protegunt contra transientes rete, quae in retibus integratis cum fontibus renovabilibus communiter occurrunt.

commodum_pic
Engineering & Global Compliance
Every TSTY Amorphous Alloy Dry-Type Transformer integrates specialized amorphous core handling with dry-type safety standards:
overview_pic_1
Amorphus nucleus sine tensione coniunctus

Stratificatio nucleo sub tensione controlata fit ut degradatio mechanica proprietatum magneticarum impediatur; verificatio perditarum sine onere post confectionem confirmat reductionem 60–70% versus basim ex ferro-silicio.

overview_pic_2
Cast-coil integritatis confirmatio

Each coil undergoes partial discharge measurement and induced voltage test per IEC 60076-11 to confirm void-free encapsulation and dielectric coordination for indoor surge environments.

overview_pic_3
Thermicae operationis verificatio

Temperature rise tested at rated load with and without fans to validate cooling system adequacy; hotspot margins documented for overload capability assessment.

overview_pic_4
Conformitas Securitatis Ignis

Materials certified to IEC 60076-11 Class F1/E2/C2, with smoke density and toxicity reports available for LEED/BREEAM sustainability documentation.

Specificationes Technicae
Standard configurations for 30–3,150 kVA amorphous alloy dry-type transformers, 10/0.4 kV or custom ratios, AN/AF cooling.
Amorphous alloy dry-type transformer parameters
Potentia Nominalis (kVA) Vector group Voltage Combination (kV) Amussis in vacuo (W) Load Loss (W) at 120°C (F) Currentis sine onere (%) Short Circuit Impedance (%)
Alta voltage Intervalum derivativum Voltaminus Inferiores
30 Dyn11 6
6.3
6.6
10
10.5
11
±5%
±2×2.5%
0.4 70 710 0.6 4
50 90 1000 0.5
80 120 1380 0.5
100 130 1570 0.5
125 150 1850 0.4
160 170 2130 0.4
200 200 2530 0.4
250 230 2760 0.4
315 280 3470 0.3
400 310 3990 0.3
500 360 4880 0.3
630 420 5880 0.3
630 410 5960 0.3 6
800 480 6960 0.3
1000 550 8130 0.2
1250 650 9690 0.2
1600 760 11700 0.2
2000 1000 14400 0.2
2500 1200 17100 0.2
1600 760 12900 0.2 8
2000 1000 15900 0.2
2500 1200 18800 0.2
Customization & Optional Features
Every TSTY Amorphous Alloy Dry-Type Transformer is built to order with options tailored for indoor, fire-sensitive, and high-efficiency applications, distinct from oil-immersed or standard dry-type offerings:
overview_pic_1
Configuratio clausurae

IP20 ventilated steel enclosure for indoor use, or IP23D stainless steel weatherproof housing for outdoor/harsh environments; removable panels for easy inspection and optional acoustic lining for noise-sensitive spaces.

overview_pic_2
Adaptatio systematis refrigerationis

Convectione aerea naturalis (AN) pro unitatibus ≤200kVA aut profilibus paucarum perditarum; ventilatores aere forzato (AF) cum controllo thermostatico pro maioribus capacitatum vel requisitis supercarricandi; setta ventilatorum redundans optabilis pro refrigeratione redundante N+1 in centris datorum gradus IV.

overview_pic_3
Strategia regulandi voltum

Off-circuit tap changer pro fix-ratio base-load applicationes, aut on-load tap changer (OLTC) pro locis cum magnis tensionis variationibus; intervala et gradus tensionis personalizabiles ad locales utilitatis tolerantes bandas.

overview_pic_4
Selectio materiae convoluti

Cuprum pro maxima efficientia et corto-circuitu fortitudine, aut aluminium pro projectis cost-sensitive cum aequivalente therma performance; utraque optio validata pro amorpho core compatibilitate et cast-coil adhaesione.

overview_pic_5
Praeparatio ad positionem intra aedificium/extra aedificium

Unitates interiores cum tegminibus superioribus contra stillationem et calefactoribus contra condensationem; unitates exteriores cum scatulis cableorum hermeticis, stratis resistentibus ultraviolettae radiationi, et arrestoribus fulminum integratis pro connexione directa ad lineas aeriennes.

overview_pic_6
Intelligentia Monitorandi Integratio

Sensores PT100 incorporati in bobinis LV et in morsibus nuclei, cum outputibus Modbus/IEC 61850 pro integratione in BMS/DCIM; numeratores temporis operationis ventilatorum et monitores resistentialis insulationis optionales pro manutentione praedictiva.

overview_pic_7
Sustainability & certification support

Placae personalizatae cum codicibus QR ad EPD/LCA relationes, calculos carbonis pedis, et instructiones de recyclatione; etiam placae verificationis efficacitatis a tertio parte pro conformitate aedificiorum viridium.

Support & Documentation
overview_pic_1
IEC-compliant datasheets and one-line diagrams
overview_pic_2
Full type-test reports (lightning impulse, etc.)
overview_pic_3
Installation, operation & maintenance manuals
overview_pic_4
Regional technical support: 24/7 engineering assistance + spare parts hubs in Asia, Africa, and the Middle East