110 kV oleum potentia transformator
110 kV oleum potentia transformator

Transformator potentiae 110 kV altae fiduciae, sine effusione, cum capacitate ad resistendum cortocircuitus provecta, pro applicationibus utilitatum et energiae renovabilis.

Conspectus
Clavis Applications
Why Choose?
INGENIARIA
Specificationes Technicae
Adaptatio ad mensuram
SUPPORT
Conspectus
Transformator electricus TSTY 110kV oleo-immersus est machina ad transmissionem altius voltatis, quae convertit 110kV in 35kV/10kV pro interconnectione rete et supplicatione industriali magnae scalae. Hic apparatus notabilis est designo suo coris sine suspensione et systemate hermetico sine perditione, attingens praestantissima domestica criteria in reductione perditionum, regula soni, et stabilitate thermica.
It is specifically validated through the National Transformer Test Center’s sudden short-circuit test, ensuring mechanical integrity under severe fault conditions. Ideal for power plants, renewable energy stations, and heavy industrial facilities, it delivers significant lifecycle cost savings through optimized efficiency and maintenance-free operation.
Clavis Applications
Communiter specificatus pro projectis ubi resistentia ad cortocircuitum, nullus perditus olei, et conformitas ad nationalia norma alti voltatis sunt critici successus factores.
overview_pic_1
Substationes utilitatis et stationes descendentis 220/110 kV
overview_pic_2
Integratio plantarum venti et photovoltaicarum in rete electricum
overview_pic_3
Magnae fabricae et complexus petrochimici
overview_pic_4
Mining operations with high-power motor loads
overview_pic_5
Thermal and hydroelectric power generation facilities
overview_pic_6
Urban grid modernization requiring low-noise equipment
Why Choose 110 kV Oil-Immersed Power Transformer?
Omnes unitates 100% aeris spiras, praecipuum oleum isolans minerale, et ferramenta galvanizata resistentia contra corrosionem habent, ut per decennia servitium fidele praestent.
Verified short-circuit withstand

Passed the National Transformer Test Center’s sudden short-circuit test on first attempt, confirming mechanical strength against electromagnetic forces during grid faults without core displacement or winding deformation.

Zero-leakage sealing system

All sealing components use die-cast construction validated via fluorescence, positive-pressure, and negative-pressure testing methods, eliminating oil seepage risks even under thermal cycling and vibration.

Stabilitas centralis sine suspensione

Elimination of the traditional suspended-core design reduces mechanical stress points and maintenance needs, thereby improving long-term reliability and simplifying field inspection procedures.

Suppressio Strepitus Avanzata

Acoustic engineering at the component level tackles noise generation at its source, achieving sound levels below national limits through optimized core clamping, tank damping, and bushing isolation.

Fabricatio in ambiente regulato

A fully enclosed production facility maintains constant temperature, humidity, and dust-free conditions, ensuring consistent insulation quality and preventing contamination during assembly.

commodum_pic
Engineering & Global Compliance
Every TSTY 110 kV oil-immersed power transformer integrates advanced manufacturing with internationally recognized quality and safety frameworks:
overview_pic_1
Simulatio vi fortuitae circuitus brevis

Analyisis finita electromagneticorum confirmat pressionem vinculi aviorum et structuram supportis nuclei ante productionem, ut integritas mechanica congruat cum performance testata verificata, non solum regulis designi empiricis innitens.

overview_pic_2
Validatio sigilli per plures methodos

Omnis componentis sigillantis fusae in forma subicitur triplici verificationi (penetratio fluorescens, retentio pressionis positivae, decrementum pressionis negativae) ut praestetur nulla perditio per omnes temperaturas operationis et cycli pressionis.

overview_pic_3
Protocolum coniunctionis in camera pura

Constant-temperature, humidity-controlled, and dust-free production environment prevents particulate contamination during core stacking and winding insertion, directly supporting low partial discharge and long-term dielectric stability.

overview_pic_4
National standard type-test alignment

Routine and type tests align with GB/T 1094 and IEC 60076 requirements, including lightning impulse, switching impulse, and induced voltage withstand; all qualified units include test reports traceable to National Transformer Test Center protocols.

Specificationes Technicae
Standard configurations for 6,300–63,000 kVA 110 kV oil-immersed power transformers.
6300–180000 / 110 kV Oil-Immersed Transformer

Capacitas nominativa (kVA)

Tensionis combinatio

Vector group

Perdita Sine Onere (kW)

Ammisso oneri
(kW) (75°C)

Correntia sine onere (%)

Impedantia (%)

Altum Voltaticum (kV)

Intervalum derivativum

Infimum Voltum (kV)

6300

110
115
121

±2x2.5%

6.3
6.6
10.5

YNd11

5.90

33

0.62

10.5

8000

7.10

40

0.62

10000

8.40

48

0.58

12500

9.90

56

0.58

16000

12.00

69

0.54

20000

14.10

84

0.54

25000

16.60

99

0.50

31500

19.70

117

0.48

40000

23.50

141

0.45

50000

28.20

166

0.42

63000

33.30

198

0.38

75000

13.8
15.75
18
21

37.80

224

0.33

12~14

90000

43.50

258

0.30

120000

54.20

320

0.27

150000

64.10

379

0.24

180000

72.00

434

0.20

 

Customization & Optional Features
Every TSTY 110 kV oil-immersed power transformer is built to order. Standard units comply with GB/T 1094 and IEC 60076, while optional features are factory-integrated and fully tested:
overview_pic_1
Tank material & finish

Carbon steel with hot-dip galvanizing for standard outdoor durability, or stainless steel for coastal/high-corrosion environments; custom RAL colour matching available for site aesthetic integration.

overview_pic_2
Configuratio expansionis olei

Sealed-tank design for maintenance-free operation in stable climates, or conservator with nitrogen blanket for high-altitude sites requiring pressure equalization and moisture exclusion.

overview_pic_3
Strategia regulandi voltum

Off-circuit tap changer for fixed-ratio applications, or on-load tap changer (OLTC) with customized step voltages and position counts to support dynamic grid voltage control; tap ranges adjustable to match utility tolerance bands.

overview_pic_4
Adaptatio pro transportu et installatione

Designum tanki humilis cum punctis fortificatis ad levandum pro itineribus transportis altitudine restrictis; rotulae robustae et cunei elevandi optionales pro positione intra aedem ubi machinae suspendentes non sunt disponibiles.

overview_pic_5
Integratio Monitoriae Conditionis

WTI/OTI sensors with analog/digital outputs and alarm/trip contacts for SCADA integration; optional dissolved gas analysis (DGA) monitors for early fault detection in critical high-voltage assets.

overview_pic_6
Optimizatio profilis amissarum

Amissae in statu inani et sub onere adaptatae ad structuras tarifarum specificas proiecti aut ad gradus regulatores efficacitatis, aequilibrans impensas capitales contra impensas operationales totius vitae, simul temperaturam crescentem tenuem servans.

overview_pic_7
Personalizatio interfaciei physicae

Adaptabilis interstitia buxorum, schemata foraminum fixationis, et positiones introitus cavi ad aptandum ad praesentes fundamentorum formae; tituli nominum disponibiles sunt in formatibus bilingualibus aut cum codicibus QR ad documenta digitalia referentibus.

Support & Documentation
overview_pic_1
IEC-compliant datasheets and one-line diagrams
overview_pic_2
Full type-test reports (lightning impulse, etc.)
overview_pic_3
Installation, operation & maintenance manuals
overview_pic_4
Regional technical support: 24/7 engineering assistance + spare parts hubs in Asia, Africa, and the Middle East