Passed the National Transformer Test Center’s sudden short-circuit test on first attempt, confirming mechanical strength against electromagnetic forces during grid faults without core displacement or winding deformation.
All sealing components use die-cast construction validated via fluorescence, positive-pressure, and negative-pressure testing methods, eliminating oil seepage risks even under thermal cycling and vibration.
Elimination of the traditional suspended-core design reduces mechanical stress points and maintenance needs, thereby improving long-term reliability and simplifying field inspection procedures.
Acoustic engineering at the component level tackles noise generation at its source, achieving sound levels below national limits through optimized core clamping, tank damping, and bushing isolation.
A fully enclosed production facility maintains constant temperature, humidity, and dust-free conditions, ensuring consistent insulation quality and preventing contamination during assembly.
Analyisis finita electromagneticorum confirmat pressionem vinculi aviorum et structuram supportis nuclei ante productionem, ut integritas mechanica congruat cum performance testata verificata, non solum regulis designi empiricis innitens.
Omnis componentis sigillantis fusae in forma subicitur triplici verificationi (penetratio fluorescens, retentio pressionis positivae, decrementum pressionis negativae) ut praestetur nulla perditio per omnes temperaturas operationis et cycli pressionis.
Constant-temperature, humidity-controlled, and dust-free production environment prevents particulate contamination during core stacking and winding insertion, directly supporting low partial discharge and long-term dielectric stability.
Routine and type tests align with GB/T 1094 and IEC 60076 requirements, including lightning impulse, switching impulse, and induced voltage withstand; all qualified units include test reports traceable to National Transformer Test Center protocols.
|
Capacitas nominativa (kVA) |
Tensionis combinatio |
Vector group |
Perdita Sine Onere (kW) |
Ammisso oneri |
Correntia sine onere (%) |
Impedantia (%) |
||
|
Altum Voltaticum (kV) |
Intervalum derivativum |
Infimum Voltum (kV) |
||||||
|
6300 |
110 |
±2x2.5% |
6.3 |
YNd11 |
5.90 |
33 |
0.62 |
10.5 |
|
8000 |
7.10 |
40 |
0.62 |
|||||
|
10000 |
8.40 |
48 |
0.58 |
|||||
|
12500 |
9.90 |
56 |
0.58 |
|||||
|
16000 |
12.00 |
69 |
0.54 |
|||||
|
20000 |
14.10 |
84 |
0.54 |
|||||
|
25000 |
16.60 |
99 |
0.50 |
|||||
|
31500 |
19.70 |
117 |
0.48 |
|||||
|
40000 |
23.50 |
141 |
0.45 |
|||||
|
50000 |
28.20 |
166 |
0.42 |
|||||
|
63000 |
33.30 |
198 |
0.38 |
|||||
|
75000 |
13.8 |
37.80 |
224 |
0.33 |
12~14 |
|||
|
90000 |
43.50 |
258 |
0.30 |
|||||
|
120000 |
54.20 |
320 |
0.27 |
|||||
|
150000 |
64.10 |
379 |
0.24 |
|||||
|
180000 |
72.00 |
434 |
0.20 |
|||||
Carbon steel with hot-dip galvanizing for standard outdoor durability, or stainless steel for coastal/high-corrosion environments; custom RAL colour matching available for site aesthetic integration.
Sealed-tank design for maintenance-free operation in stable climates, or conservator with nitrogen blanket for high-altitude sites requiring pressure equalization and moisture exclusion.
Off-circuit tap changer for fixed-ratio applications, or on-load tap changer (OLTC) with customized step voltages and position counts to support dynamic grid voltage control; tap ranges adjustable to match utility tolerance bands.
Designum tanki humilis cum punctis fortificatis ad levandum pro itineribus transportis altitudine restrictis; rotulae robustae et cunei elevandi optionales pro positione intra aedem ubi machinae suspendentes non sunt disponibiles.
WTI/OTI sensors with analog/digital outputs and alarm/trip contacts for SCADA integration; optional dissolved gas analysis (DGA) monitors for early fault detection in critical high-voltage assets.